Camera with PIR sensor function CB-8007SP.CB-8008SP.CC-9008SP.CC-9008SAP |
||||||||||||
|
Installation and descriptions: |
||||||||||||
| 1.LED Selector | ||||||||||||
|
|
|
Walk-testing: |
Position black cap on the Top and Center pin.
|
|||||||||
|
(3 PINS: Top, Center, and Bottom) |
Disable Walk-test: |
Position black cap on the Bottom and Center pin. |
||||||||||
|
|
||||||||||||
| 2.Sensitivity Adjustment | ||||||||||||
![]() |
To raise sensitivity: |
Turn VR clockwise to detect longer distance and wider pattern. |
||||||||||
|
To lower sensitivity: |
Turn VR counter clockwise. |
|||||||||||
| 3.Dwell Time Adjustment: | ||||||||||||
|
|
For closure period of N.C/N.O relay connected to an alarm panel, light control or recording control of time lapse VCR, etc. |
|||||||||||
|
A |
Max. Time: |
Turn clockwise |
||||||||||
|
B |
Min. Time: |
Turn counter clockwise |
||||||||||
|
Adjustable from 2 to 40 sec |
||||||||||||
|
4.Pulse Control: |
||||||||||||
![]() |
Pulse 1: |
Move black cap over Pair 1. |
||||||||||
|
Pulse 2: |
Move black cap over Pair 2. |
|||||||||||
|
(Triggering starts after 2 detection within 15 sec.) |
||||||||||||
|
1-2 Pulse |
||||||||||||
|
5. Connection Terminals: |
||||||||||||
|
N.O.: |
Normal Open |
|||||||||||
![]() |
(For connection to security panel, light control, CCTV etc.) |
|||||||||||
|
N.C.: |
Normal Closed |
|||||||||||
|
p.s. Relay Output Current: 1A 125VAC ( 2A 30 VDC) |
||||||||||||